开放获取期刊获得更多读者和引用
700 种期刊 和 15,000,000 名读者 每份期刊 获得 25,000 多名读者
Sena Caglar and Ali Rahmi Alp
In this paper a simple, precise and rapid high performance liquid chromatography method with UV detection has been developed for the determination of saxagliptin and metformin in bulk. An Agilent, Zorbax CN (250 × 4.6 mm I.D., 5 μm) column was used with a mobile phase mixture of methanol-50 mM phosphate buffer (pH 2.7) in a gradient elution mode at a flow rate of 1.0 ml min-1. The analytes were detected at 225 nm and total run time for the method was 7 min. The calibration graphs were linear in the range of 5.00-125.00 μg ml-1 for saxagliptin and 2.50-62.50 μg ml-1 for metformin. For stability indicating study, saxagliptin was subjected to acid, neutral and alkali hydrolysis, oxidation and heat stress. The developed method could be used for quality control assay for SAX in tablets and for stability studies as the method separates SAX from its degradation products and tablet excipients.