国际标准期刊号: ISSN:2167-7964

放射学组学杂志

开放获取

我们集团组织了 3000 多个全球系列会议 每年在美国、欧洲和美国举办的活动亚洲得到 1000 多个科学协会的支持 并出版了 700+ 开放获取期刊包含超过50000名知名人士、知名科学家担任编委会成员。

开放获取期刊获得更多读者和引用
700 种期刊 15,000,000 名读者 每份期刊 获得 25,000 多名读者

索引于
  • 哥白尼索引
  • 谷歌学术
  • 打开 J 门
  • Genamics 期刊搜索
  • 研究圣经
  • 电子期刊图书馆
  • 参考搜索
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-世界猫
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 日内瓦医学教育与研究基金会
  • ICMJE
分享此页面

抽象的

Accuracy of Cystosonography without Voiding Phase in the Diagnosis of Vesicoureteral Reflux in Children: A Variant of the Original Technique

Carmela Visalli, Nunziella Sicilia, Ignazio Salamone, Roberto Chimenz, Carmelo Fede and Stefania Mondello

Background: Voiding urosonography (VUS) can assess vesicoureteral reflux (VUR) in children. However, during examination, the voiding phase may create management problems for the operator as well as psychological disorders for the patient.

Objective: To assess diagnostic accuracy of cystosonography with the Valsalva maneuver (Valsalvacystosonography) instead of voiding phases in the evaluation of VUR in children and compares this new technique with traditional VUS.

Materials and methods: A total of 41 kidney-ureter-units (KUU) were assessed in 22 children (11 girls and 11 boys, mean age 5.6 years old, range 4 to 9 years) who were referred to our Institution for evaluation of VUR. Clinical indications included urinary tract infection without pelvicalyceal and ureter dilatation, pelvicalyceal and ureter dilatation without urinary tract infection or both. Children were eligible if they were able to carry out the Valsalva maneuver. All patients were informed on how to perform the Valsalva maneuver before the exam was performed. Valsalva-cystosonography and VUS were consecutively carried out in the same patient. The voiding phase was performed by another examiner in all patients.

Results: VUR was detected in 16 (39%) of the 41 KUUs. In 15 KUUs (36.6%), reflux was detected with both methods. In 1 patient, grade II reflux was detected by VUS only. The agreement between VUS and Valsalvacystosonography was 0.96 (p < 0.0001), which indicates an “almost perfect agreement”. Taking the VUS as the reference standard, Valsalva-cystosonography had a sensitivity of 93.75% (95% CI 69.77% - 99.84%) and a specificity of 100% (95% CI 86.28% - 100%). The grade of VUR detected with Valsalva-cystosonography also showed moderate agreement with grading by voiding VUS [κ = 0.51, p = 0.002].

Conclusion: Our results demonstrate that the Valsalva-cystosonography is an effective approach for assessing VUR and support its potential use as an alternative to the traditional voiding phase.

免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证。