国际标准期刊号: 2155-9872

分析与生物分析技术杂志

开放获取

我们集团组织了 3000 多个全球系列会议 每年在美国、欧洲和美国举办的活动亚洲得到 1000 多个科学协会的支持 并出版了 700+ 开放获取期刊包含超过50000名知名人士、知名科学家担任编委会成员。

开放获取期刊获得更多读者和引用
700 种期刊 15,000,000 名读者 每份期刊 获得 25,000 多名读者

索引于
  • CAS 来源索引 (CASSI)
  • 哥白尼索引
  • 谷歌学术
  • 夏尔巴·罗密欧
  • 学术期刊数据库
  • 打开 J 门
  • Genamics 期刊搜索
  • 期刊目录
  • 研究圣经
  • 中国知网(CNKI)
  • 乌尔里希的期刊目录
  • 电子期刊图书馆
  • 参考搜索
  • 研究期刊索引目录 (DRJI)
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-世界猫
  • 学者指导
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 欧洲酒吧
  • ICMJE
分享此页面

抽象的

An Ultra-Sensitive LC Method for Simultaneous Determination of Rosuvastatin, Alprazolam and Diclofenac Sodium in API, Pharmaceutical Formulations and Human Serum by Programming the Detector

Najma Sultana, Muhammad Saeed Arayne and Saeeda Nadir Ali

Here, we report a rapid and efficient liquid chromatographic method with UV detection for the simultaneous determination of rosuvastatin, alprazolam and diclofenac sodium in API, pharmaceutical formulations and human serum employing a reversed phase Bondapak C18 (25 cm, 0.46 cm, 10 μm) column at room temperature using methanol: water (80:20 v/v) and pH adjusted to 2.9 with 85% o-phosphoric acid. Separation was achieved within a time span of 6 min. The detector response was monitored at 240 nm and the flow rate was set at 1.0 mL.min-1. Various LC parameters were optimized and developed method was validated as per ICH (2006) guidelines. Linear calibration range was determined to be 0.02-0.64, 0.125-4.0 and 0.05-1.6 μg.mL-1 and detection and quantitation limits were found to be 4.0, 17.0, 7.0 and 12.0, 52.0, 22.0 ng.mL-1 for rosuvastatin, alprazolam and diclofenic sodium respectively. Method was linear for all analytes with correlation coefficients >0.998. The intra-day and inter-day accuracy and precision of the assay were in acceptable range of 98.21-101.91% recovery and 0.20-2.07% RSD. The sensitivity of the method was enhanced when the chromatograms were analyzed by programming the detector at individual λmax of 244, 222 and 284 nm for rosuvastatin, alprazolam and diclofenac sodium respectively. High peak intensity was observed on injecting same sample concentration after the detector was programmed. Linearity was obtained even at lower concentrations of 0.02-0.64, 0.05-1.60 and 0.02-0.64 μg.mL-1. LOD and LOQ values shifted down to 3.0, 6.0, 1.0 and 9.0, 19.0, 3.0 ng.mL-1 respectively. Recovery was found to be in the range of 98.32-101.87% and inter-day and intra-day precision was less than 2.10%. The proposed method was found to be robust and successfully employed for the determination of studied drugs in commercial formulations and human serum without interference of excipients or endogenous components of serum.

免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证。