国际标准期刊号: 2157-2526

生物恐怖主义和生物防御杂志

开放获取

我们集团组织了 3000 多个全球系列会议 每年在美国、欧洲和美国举办的活动亚洲得到 1000 多个科学协会的支持 并出版了 700+ 开放获取期刊包含超过50000名知名人士、知名科学家担任编委会成员。

开放获取期刊获得更多读者和引用
700 种期刊 15,000,000 名读者 每份期刊 获得 25,000 多名读者

索引于
  • CAS 来源索引 (CASSI)
  • 哥白尼索引
  • 谷歌学术
  • 夏尔巴·罗密欧
  • 打开 J 门
  • Genamics 期刊搜索
  • 学术钥匙
  • 期刊目录
  • 研究圣经
  • 中国知网(CNKI)
  • 乌尔里希的期刊目录
  • 参考搜索
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-世界猫
  • SWB 在线目录
  • 普布隆斯
  • 日内瓦医学教育与研究基金会
  • 欧洲酒吧
  • ICMJE
分享此页面

抽象的

Detection Efficiency Comparison of the UV-APS and TACBIO using Inert Fluorescent and Biological Particles

Praveena Mylvaganam, Valerie Alstadt, Gary Kilper, Aime Goad and Jana Kesavan

Airborne CB threats have evolved into a serious and omnipresent battlefield threat against US military forces. Real time detection of these agents is an essential tool in the war against terrorism; government agencies employ fluorescent based aerosol detectors to provide real-time detection of these airborne biological particles. The TSI Model 3314 UVAPS has been used as the gold standard in military studies for detecting and quantifying airborne bio-threat particles for many years, however, the system was designed for laboratory applications and has several drawbacks; it is bulky, very expensive, and is no longer in production. This study evaluated the performance of a small and inexpensive aerosol detector, the TACBIO, as a low cost alternative to the UV-APS in aerosol detection. In this test, both systems were evaluated against aerosolized monodispersed polystyrene latex microspheres (PSLs) (1.4, 1.9, and 2.6 μm) and monodisperse bacteria spore clusters. Three Bacillus anthracis Ames simulant organisms were used in the bio test: Bacillus atrophaeus var. globigii (Bg), Bacillus thuringiensis (Bt), Bacillus anthracis Sterne (BaS). In the second part of the test, the counting efficiency of both instruments were compared by sampling 3 μm fluorescent PSL microspheres from a chamber. The counts obtained from both instruments were correlated to determine how well their detection efficiencies match up. The resulting data demonstrate that the TACBIO tracks the detection efficiency of UV-APS very well when sampling 3 μm PSL microspheres. The detection efficiency of the UV-APS and TACBIO were close to 100% for PSL microspheres and Bt and BaS particles, however, the TACBIO results for Bg were slightly lower due to the lower fluorescence properties of Bg. In spite of this minor difference, the TACBIO performed well in comparison to the much more expensive UV-APS systemes.