国际标准期刊号: ISSN:2167-7964

放射学组学杂志

开放获取

我们集团组织了 3000 多个全球系列会议 每年在美国、欧洲和美国举办的活动亚洲得到 1000 多个科学协会的支持 并出版了 700+ 开放获取期刊包含超过50000名知名人士、知名科学家担任编委会成员。

开放获取期刊获得更多读者和引用
700 种期刊 15,000,000 名读者 每份期刊 获得 25,000 多名读者

索引于
  • 哥白尼索引
  • 谷歌学术
  • 打开 J 门
  • Genamics 期刊搜索
  • 研究圣经
  • 电子期刊图书馆
  • 参考搜索
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-世界猫
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 日内瓦医学教育与研究基金会
  • ICMJE
分享此页面

抽象的

False-Negative 99mTc Medi-MIBI Parathyroid Scintigraphies: A Report on the Possible Role of Diagnostic Two-Phase Single-Acquisition CT

Afzelius P, Iyer V, Lelkaitis G and Henriksen SD

Introduction: Dual-phase 99mTc-Medi-MIBI parathyroid scintigraphy is often used for preoperative localization of
primary parathyroid adenomas. The overall accuracy has been reasonably high; however, some false-negative cases
occasionally occur. Two such cases are presented, and the advantages of adding two-phased single-acquisition
diagnostic CT to guide the surgeon are demonstrated.

Case presentations: A 54-year old male was admitted due to persistent elevated parathyroid hormone and
calcium concentrations in the blood despite medical treatment consistent with primary hyperparathyroidism. A dualphase
parathyroid scintigraphy performed 6 months earlier in another hospital was unable to confirm the diagnosis.
There was no change over time in levels of parathyroid hormone and calcium in the blood. In the second case, a 46-
year old woman was examined due to the same symptoms and findings; 18 months earlier she also had no retention
of tracer on late images. In this case, the patient also had had a CT performed, which showed morphological signs
of a parathyroid adenoma. We therefore planned dual-phase parathyroid scintigraphy with single-photon emission
computed tomography/computed tomography (SPECT/CT) in the early phase. The low-dose CT was unable to confirm
the impression of slight amounts of tracer uptake and retention at the lower right thyroid pole in both cases. Diagnostic
in both cases, but still with a low dose, the CT revealed a parathyroid adenoma situated in a common parathyroid
location at the lower pole of the right thyroid lobe, where activity retention was seen in late images. The surgeon was
able to perform minimally invasive neck surgery based on accurate anatomical localization of the adenoma.
Conclusion: This case report highlights the potential of two-phase single-acquisition CT as a useful tool in exact
localization of parathyroid adenoma for guiding the surgeon in minimally invasive surgery.

免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证。