国际标准期刊号: ISSN:2167-7964

放射学组学杂志

开放获取

我们集团组织了 3000 多个全球系列会议 每年在美国、欧洲和美国举办的活动亚洲得到 1000 多个科学协会的支持 并出版了 700+ 开放获取期刊包含超过50000名知名人士、知名科学家担任编委会成员。

开放获取期刊获得更多读者和引用
700 种期刊 15,000,000 名读者 每份期刊 获得 25,000 多名读者

索引于
  • 哥白尼索引
  • 谷歌学术
  • 打开 J 门
  • Genamics 期刊搜索
  • 研究圣经
  • 电子期刊图书馆
  • 参考搜索
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-世界猫
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 日内瓦医学教育与研究基金会
  • ICMJE
分享此页面

抽象的

Image Quality and Radiation Dose Comparison between Filtered Back Projection and Adaptive Statistical Iterative Reconstruction in Non-contrast Head CT Studies

Seth Alper, Prasoon Mohan, Ian Chaves, Richard Kane and Joseph Calandra

Purpose: The goal of the study was to compare the total radiation dose and subjective image quality between conventional Filtered Back Projection (FBP) and Adaptive Statistical Iterative Reconstruction (ASIR) in non-contrast head CT. Method: Forty seven patients underwent non contrast head CT with image reconstruction using 100% FBP. The same set of patients underwent subsequent non contrast head CT within 6 months using combination of ASIR and FBP reconstruction. Institutional Review Board approval was obtained. Objective assessment of total radiation dose was obtained by measuring the dose length product (DLP) and effective radiation dose. Subjective image quality was assessed by 2 attending radiologists who were blinded to the scanning technique. All images were graded for sharpness, image noise and overall image quality on a 5 point Likert scale. Both subjective and objective measurements from the two sets of images were compared. Paired Student’s t-Test was used for statistical analysis. Results: There was a significant reduction in DLP with the application ASIR from 1781.7 (310) to 1098.9 (SD 281.4) mGy-cm (p<0.01), resulting in mean total dose reduction of 38.4%. The total effective dose also showed similar reduction from 3.9 (SD 0.68) to 2.4 (SD 0.62) mSv (P<0.01). Subjective score for image noise was 4.44 (SD 0.43) and 4.40 (SD 0.48), before and after application of ASIR, respectively (p=0.59). Overall image quality scores were 4.87 (SD 0.33) and 4.85 (0.36) before and after application of ASIR, respectively (p=0.12). Subjective scores for image sharpness decreased after application of ASIR from 4.94 (SD 0.24) to 4.77 (SD 0.47) (p=0.04) Conclusion: Compared to conventional FBP reconstruction, combination of ASIR with FBP reconstruction results in significant reduction in total radiation dose without affecting the overall image quality in non-contrast head CT.