国际标准期刊号: 2155-9872

分析与生物分析技术杂志

开放获取

我们集团组织了 3000 多个全球系列会议 每年在美国、欧洲和美国举办的活动亚洲得到 1000 多个科学协会的支持 并出版了 700+ 开放获取期刊包含超过50000名知名人士、知名科学家担任编委会成员。

开放获取期刊获得更多读者和引用
700 种期刊 15,000,000 名读者 每份期刊 获得 25,000 多名读者

索引于
  • CAS 来源索引 (CASSI)
  • 哥白尼索引
  • 谷歌学术
  • 夏尔巴·罗密欧
  • 学术期刊数据库
  • 打开 J 门
  • Genamics 期刊搜索
  • 期刊目录
  • 研究圣经
  • 中国知网(CNKI)
  • 乌尔里希的期刊目录
  • 电子期刊图书馆
  • 参考搜索
  • 研究期刊索引目录 (DRJI)
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-世界猫
  • 学者指导
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 欧洲酒吧
  • ICMJE
分享此页面

抽象的

Method for Discovery of Peptide Reagents Using a Commercial Magnetic Separation Platform and Bacterial Cell Surface Display Technology

Deborah A. Sarkes, Brandi L. Dorsey, Amethist S. Finch and Dimitra N. Stratis-Cullum

Biopanning by bacterial display has many advantages over yeast and phage display, including the speed to discovery of affinity reagents and direct amplification of bound cells without the need to elute and reinfect. However, widespread use is limited, in part due to poor performance achieved using manual Magnetic-Activated Cell Sorting (MACS) methods, and an absence of widely-available, low cost, high-performance sorting alternatives. Here, we have developed a methodology for bacterial cell sorting using the semi-automated autoMACS® Pro Separator for the first time, and have produced a complete method for sorting of bacteria displaying 15-mer peptides on their cell surface using this device, including downstream bioinformatic analysis of candidates for binding to a target of interest. Two autoMACS® programs designed for isolation of target cells with low frequency were evaluated and adapted to bacterial biopanning, using protective antigen (PA) of Bacillus anthracis as the model system. In contrast to manual MACS, the bacterial display library was preferentially enriched by autoMACS® sorting, yielding several promising candidates after only three rounds of biopanning and bioinformatic analysis. Individual candidates were evaluated for relative binding to fluorescently-labeled PA target or streptavidin negative control using Fluorescence-Activated Cell Sorting (FACS). The top thirteen peptide candidates from the autoMACS® sort demonstrate binding to PA with low cross-reactivity to streptavidin, while only two of eighteen candidates from the manual sort showed binding to PA, and both demonstrated greater cross-reactivity to streptavidin. Overall, the autoMACS® platform quickly harvested higher affinity peptide candidates with demonstrated specificity to the PA target. Peptide candidates produced with this method contained the previously reported PA consensus WXCFTC, further validating this method and the commercially available autoMACS® platform as the first low cost, semi-automated biopanning approach for bacterial display that is widely accessible and more reliable than the MACS/FACS standard protocol.

免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证。