国际标准期刊号: 2155-9872

分析与生物分析技术杂志

开放获取

我们集团组织了 3000 多个全球系列会议 每年在美国、欧洲和美国举办的活动亚洲得到 1000 多个科学协会的支持 并出版了 700+ 开放获取期刊包含超过50000名知名人士、知名科学家担任编委会成员。

开放获取期刊获得更多读者和引用
700 种期刊 15,000,000 名读者 每份期刊 获得 25,000 多名读者

索引于
  • CAS 来源索引 (CASSI)
  • 哥白尼索引
  • 谷歌学术
  • 夏尔巴·罗密欧
  • 学术期刊数据库
  • 打开 J 门
  • Genamics 期刊搜索
  • 期刊目录
  • 研究圣经
  • 中国知网(CNKI)
  • 乌尔里希的期刊目录
  • 电子期刊图书馆
  • 参考搜索
  • 研究期刊索引目录 (DRJI)
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-世界猫
  • 学者指导
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 欧洲酒吧
  • ICMJE
分享此页面

抽象的

Quantification of Dimethylacetamide and its Primary Metabolite Monomethylacetamide in Plasma Using Robust LC-MS Method

Fadwa Benkessou, Ibrahim El Serafi, Brigitte Twelkmeyer, Manuchehr Abedi-Valugerdi and Moustapha Hassan

N,N-Dimethylacetamide (DMA) is an excellent solvent that is highly used in the production of synthetic fibres as well as in the pharmaceutical industry. It is present as a solvent in the intravenous formulation of busulphan, a drug used in high doses as myeloablative treatment prior to hematopoietic stem cell transplantation (SCT). DMA was shown to cause hepatotoxicity as well as neurotoxicity, as revealed throughout several studies including phase I study. In the present investigation we developed an LC-MS based method to detect and quantify DMA and its primary metabolite N-monomethylacetamide (MMA) simultaneously in human plasma, using a C-18 ODS-AQ/S-5 µm 12 nm separation column. The lower limits of quantification (LLOQs) for DMA and MMA were 1.8 µM and 8.6 µM, respectively. The limit of detection (LOD) for DMA and MMA were 0.53 µM and 2.52 µM, respectively. The recovery of DMA from plasma ranged from 97-101% and for MMA from 76-100%. The stability for DMA and MMA was assessed through freeze-thaw cycles and storage at different temperatures (RT, 4°C and -20°C for three days); the results have shown <7.9% CV for DMA and <14.1% for MMA. The inter-day and intra-day variation assay accuracy and precision was <6.3% for DMA and <8.6% for MMA. The calibration was linear within the ranges 1 to 4000 µM. The method was applied to follow the kinetics and to quantify DMA and its metabolite MMA in 49 plasma samples from 2 patients undergoing SCT and treated with intravenous busulphan that contain DMA. The present method is simple, robust and showed good selectivity with high accuracy, precision and reproducibility. Moreover, it can be utilized to determine DMA and its metabolite in workers, patients and environment and hence avoid toxic exposure.

免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证。