国际标准期刊号: 2155-9872

分析与生物分析技术杂志

开放获取

我们集团组织了 3000 多个全球系列会议 每年在美国、欧洲和美国举办的活动亚洲得到 1000 多个科学协会的支持 并出版了 700+ 开放获取期刊包含超过50000名知名人士、知名科学家担任编委会成员。

开放获取期刊获得更多读者和引用
700 种期刊 15,000,000 名读者 每份期刊 获得 25,000 多名读者

索引于
  • CAS 来源索引 (CASSI)
  • 哥白尼索引
  • 谷歌学术
  • 夏尔巴·罗密欧
  • 学术期刊数据库
  • 打开 J 门
  • Genamics 期刊搜索
  • 期刊目录
  • 研究圣经
  • 中国知网(CNKI)
  • 乌尔里希的期刊目录
  • 电子期刊图书馆
  • 参考搜索
  • 研究期刊索引目录 (DRJI)
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-世界猫
  • 学者指导
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 欧洲酒吧
  • ICMJE
分享此页面

抽象的

Quantitation of Insulin Analogue Glargine and Its Two Metabolites M1 and M2 on Triple Quad 6500 and Triple TOF 5600 LC-MS/MS Systems in a Dog Toxicokinetics Study

Yong-Xi Li, Yan Ke, Junyu Li, Yu Li, Run Li, Xiaofeng Chen, Sahana Mollah and Xu Wang

Glargine is a long lasting bioengineered insulin analogue commonly used in the medical treatment of insulindependent diabetes mellitus. After subcutaneous injection, glargine undergoes enzymatic process generating two metabolites, M1 and M2. Quantitative evidences of their presence and concentration after doping multiple concentrations are important for clinical study. Such information can also help to understand the pharmacokinetics, pharmacodynamics, and toxicology during the insulin drug development. We developed and validated a high throughput analytical method coupled with solid-phase extraction (SPE) and LC-MS/MS for the quantitation of intact insulin in plasma samples for use in pre-clinical and clinical studies. The multiple-reaction-monitoring (MRM) experiments performed on a triple-quadruple mass spectrometry instrument were used for quantitation. A 3.5 min UHPLC method was developed to achieve high throughput. An eight-point standard calibration curve with concentration from 0.2 ng/mL to 20 ng/mL was constructed corresponding to the normal non-fasting insulin levels in plasma. The acceptance criteria for values of accuracy, precision, and linearity of the quantitation curve were developed in accordance to the bioanalytical method validation guidance published by Food and Drug Administration (FDA) and European Medicines Agency (EMA). This validated MRM method was applied for toxicity study of insulin analogues in dog. The toxicokinetic results were reported. Moreover, we compared the MRM results to the MS quantitation results acquired on a hybrid quadruple-quadruple time-of-flight (QqTOF) and showed the high resolution instrument can be an option for peptide and biotherapeutic protein quantitation.