开放获取期刊获得更多读者和引用
700 种期刊 和 15,000,000 名读者 每份期刊 获得 25,000 多名读者
Kiyoaki Tsukahara *,Kazuhiro Nakamura ,Ray Motohashi ,Hiroki Sato ,Mamoru Suzuki
Objectives: The purpose of the present study was to show the technique of the Harmonic FOCUS® Cured Shears (HF) in tracheostomy in the shortest possible period of time.
Methods: Patients were 10 individuals who had undergone tracheostomy at Tokyo Medical University Hachioji Medical Center. HF was used in the all 10 patients. A skin incision was made in the inferior margin of the cricoid cartilage, and FOCUS® was used from treatment of subcutaneous fat onwards. FOCUS® was used both to dissect the subcutaneous fat, as well as the anterior muscles of the neck and anterior jugular vein, and to seal these parts. The pyramidal lobe of the thyroid gland was transected at a height directly below the cricoid cartilage, and the trachea was reached.
Results: The mean time taken to reach the trachea was 93.1 s (range, 63-115 s). Conclusions: The HF is useful for tracheostomy and enables an airway to be secured within a short period of time.