国际标准期刊号: 2155-9872

分析与生物分析技术杂志

开放获取

我们集团组织了 3000 多个全球系列会议 每年在美国、欧洲和美国举办的活动亚洲得到 1000 多个科学协会的支持 并出版了 700+ 开放获取期刊包含超过50000名知名人士、知名科学家担任编委会成员。

开放获取期刊获得更多读者和引用
700 种期刊 15,000,000 名读者 每份期刊 获得 25,000 多名读者

索引于
  • CAS 来源索引 (CASSI)
  • 哥白尼索引
  • 谷歌学术
  • 夏尔巴·罗密欧
  • 学术期刊数据库
  • 打开 J 门
  • Genamics 期刊搜索
  • 期刊目录
  • 研究圣经
  • 中国知网(CNKI)
  • 乌尔里希的期刊目录
  • 电子期刊图书馆
  • 参考搜索
  • 研究期刊索引目录 (DRJI)
  • 哈姆达大学
  • 亚利桑那州EBSCO
  • OCLC-世界猫
  • 学者指导
  • SWB 在线目录
  • 虚拟生物学图书馆 (vifabio)
  • 普布隆斯
  • 欧洲酒吧
  • ICMJE
分享此页面

抽象的

Utility of Ion-Pair and Charge Transfer Complexation for Spectrophotometric Determination of Domperidone and Doxycycline in Bulk and Pharmaceutical Formulations

Amr L. Saber and Alaa S. Amin

Four simple, sensitive, and accurate spectrophotometric methods (A-D) have been developed for the determination of domperidone (I) and doxycycline (II) in bulk and in pharmaceutical formulations. The first two methods (A and B) are based on the formation of yellow ion-pair complexes between the examined drugs with bromocresol green (BCG) and methyl orange (MO) as chromophoric reagents in Britton-Robinson (B-R) universal buffer of pH 3.0 and 2.2, respectively. The formed complexes were extracted with chloroform and measured at 420 nm and 424 nm for I and II using BCG, respectively and 480 nm for the studied drugs using MO. The last two methods (C and D) are based on charge transfer complex formation between the studied drugs and tetracyanoethylene (TCNE); and 7,7,8,8-tetracyanoquinodimethane (TCNQ). Different variables affecting the reactions were studied and optimized. Under the optimum reaction conditions, linear relationships with good correlation coefficients (0.9992 - 0.9998) were found between the absorbance and the concentration of I in the range of 1.4-22.4μg mL −1 , whereas that for II in the range 1.4-25.5μg mL −1 . For more accurate analysis, Ringbom optimum concentration range was found to be between 3.0-21.5 and 3.0-23.5μg mL −1 , for I, and II, respectively. Sandell’s sensitivity, correlation coefficient, and limits of detection and quantification were calculated for each method. A Job’s plot of the absorbance versus the molar ratio of drug to each of formed complex under consideration indicated (1:1) ratio. No interference was observed from common pharmaceutical excipients and additives. Statistical comparison of the results with those obtained by the official method shows excellent agreement and indicates no significant difference in accuracy and precision.

免责声明: 此摘要通过人工智能工具翻译,尚未经过审核或验证。